This shows you the differences between two versions of the page.
|
hardware:modules:mod-com4 [2012/08/10 01:31] aaron created |
hardware:modules:mod-com4 [2013/09/02 05:03] (current) jarrod [Front Pinouts] |
||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== MOD-COM4 ====== | ====== MOD-COM4 ====== | ||
| + | The MOD-COM4 is a modular unit capable of up to 4 x RS232 ports, also configurable for RS422 and RS485.\\ | ||
| + | |||
| + | ===== Quick Reference Guide ===== | ||
| + | |||
| + | The Modules Quick Reference Guide provides the basic information required to get started on a printable, black and white document that can be easily taken with you to a job site. [[http://www.commandfusion.com/docs/quick/QuickReferenceGuide-Modules.pdf|Find the Modules Quick Reference Guide here.]] | ||
| + | |||
| + | |||
| + | ===== Ports ===== | ||
| + | |||
| + | Front of the module has two 6-pin connectors, the top row and bottom row.\\ | ||
| + | Each row can be configured as either:\\ | ||
| + | * 2 x RS232 without flow control | ||
| + | * 1 x RS232 with flow control | ||
| + | * 1 x RS485 half-duplex | ||
| + | * 1 x RS485/422 full-duplex | ||
| + | Note that when using any RS232 mode in combination with RS485 or RS422 (any duplex type), the RS232 must be on ports 3 and/or 4 (bottom row).\\ | ||
| + | RS232 can never be in ports 1 or 2 (top row) when using alongside RS485 or RS422 (bottom row).\\ | ||
| + | \\ | ||
| + | For more details on the MOD-COM4 port configuration options, please see the [[hardware:cflink:com-module-cflink-documentation|MOD-COM4 CFLink documentation]].\\ | ||
| + | |||
| + | ==== Front Pinouts ==== | ||
| + | Pinouts for the various modes each connector can be configured to are as follows:\\ | ||
| + | {{:hardware:modules:com4-pinout.svg|}} | ||
| + | |||
| + | **2 x RS232 without flow control** | ||
| + | - TX-1 | ||
| + | - Ground | ||
| + | - RX-1 | ||
| + | - TX-2 | ||
| + | - Ground | ||
| + | - RX-2 | ||
| + | |||
| + | **1 x RS232 with flow control** | ||
| + | - TX | ||
| + | - Ground | ||
| + | - RX | ||
| + | - RTS | ||
| + | - Ground | ||
| + | - CTS | ||
| + | |||
| + | **1 x RS485 half-duplex** | ||
| + | - Data + (B) | ||
| + | - Ground | ||
| + | - Not Connected | ||
| + | - Data - (A) | ||
| + | - Ground | ||
| + | - Not Connected | ||
| + | |||
| + | **1 x RS485/422 full-duplex** | ||
| + | - TX + | ||
| + | - Ground | ||
| + | - RX + | ||
| + | - TX - | ||
| + | - Ground | ||
| + | - RX - | ||
| + | |||
| + | ==== Rear Connector ==== | ||
| + | The rear of every module contains a module port, used to connect the module into the modular controller base unit (DIN-MOD4, etc).\\ | ||
| + | The pinout for this port is not published (as it has no benefit to any user). | ||
| + | |||