CommandFusion Wiki

Documentation Resources

User Tools

Site Tools


hardware:modular-base-units:din-mod4

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

hardware:modular-base-units:din-mod4 [2012/08/10 01:20]
aaron created
hardware:modular-base-units:din-mod4 [2013/09/02 03:45] (current)
aaron [Module Slots]
Line 1: Line 1:
 ====== DIN-MOD4 ====== ====== DIN-MOD4 ======
  
-The CommandFusion DIN-MOD4 is a modular controller, capable of housing 4 modules, in any combination.\\+The CommandFusion DIN-MOD4 is a DIN-Rail mountable ​modular controller, capable of housing 4 modules, in any combination.\\
 You could for instance load it up with 4 IR modules, giving a total of 32 IR ports. Or perhaps 4 COM4 modules, giving a maximum of 17 RS232 ports (including the on-board RS232 port).\\ You could for instance load it up with 4 IR modules, giving a total of 32 IR ports. Or perhaps 4 COM4 modules, giving a maximum of 17 RS232 ports (including the on-board RS232 port).\\
  
Line 67: Line 67:
 ==== On-Board Digital Input ==== ==== On-Board Digital Input ====
  
-This digital input can be used to trigger rules in the CFLink network.\\ +This dry contact ​digital input can be used to trigger rules in the CFLink network.\\ 
 +  - Input 
 +  - Ground
 ==== CFLink x 2 ==== ==== CFLink x 2 ====
  
Line 79: Line 80:
   - Data +   - Data +
   - Data -   - Data -
-  - Power (12-24V DC)+  - Power (9-30V DC)
   - Ground   - Ground
  
Line 87: Line 88:
  
 ===== Module Slots ===== ===== Module Slots =====
-The 4 module slots can be used for any combination of modules.\\+The 4 module slots can be used for any combination of [[hardware:modules:|modules]].\\
 \\ \\
 Use a flat head screw driver (preferably plastic to avoid marking, but metal is fine too) to lever the modules out far enough to pull out the remaining amount with your fingers.\\ Use a flat head screw driver (preferably plastic to avoid marking, but metal is fine too) to lever the modules out far enough to pull out the remaining amount with your fingers.\\
Line 95: Line 96:
 After inserting a module, you will need to reset the DIN-MOD4 before that module is detected.\\ After inserting a module, you will need to reset the DIN-MOD4 before that module is detected.\\
  
 +==== Module Pinouts ====
 +You can find [[hardware:​modules|documentation for each module]] and the relevant page in our [[hardware:​modules|modules section]].
 +===== Factory Reset =====
 +For information on how to rest your device to factory settings, see the [[hardware:​device-resetting|Device Resetting Page]].
hardware/modular-base-units/din-mod4.1344561615.txt.gz · Last modified: 2012/08/10 01:20 by aaron