 ====== DIN-RY CFLink Protocol ====== ====== DIN-RY CFLink Protocol ======
  
-The following documentation is for the DIN-RYx-N devices CFLink protocol messages.+The following documentation is for the DIN-RYx-N devices CFLink protocol messages. ​This protocol can be used regardless of connection method to the DIN-RYx device either via USB, RS232 or RS485. 
 + 
 +===== Control Port Configuration ===== 
 + 
 +This command is used to configure the communication properties for each control port on the unit. 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]CCFXSPC[F4]<​PORT>:<​MODE>:<​BAUD>:<​DATABITS>:<​PARITY>:<​STOP>:<​FLOW CONTROL>​[F5][F5] 
 +</​sxh>​ 
 + 
 +* **<​PORT>​** would be designated as: 
 +       * P01 = RS232 IN 
 +       * P02 = RS485 IN 
 +       * P03 = RS485 OUT 
 +       * P04 = RS232 OUT 
 +       * PZZ = All Ports 
 + 
 +* **<​MODE>​** would be designated as: 
 +       * BUS (Bus Mode) - Messages are to be treated as control protocol commands and forwarded along the bus as per the Message Handling documentation. Available <​BAUD>​ rates would be 115200 (default) and 38400. 
 + 
 +<sxh cflink; light: true> 
 +> [F2][20][F3]CCFXSPC[F4]P04:​BUS:​115200:​8:​N:​1:​0[F5][F5] 
 +</​sxh>​ 
 + 
 +       * EXT (External Mode) - Messages sent to/from a third party device, allowing control of other RS232 or RS485 devices via rules and macros. Available <​BAUD>​ rates would be: 
 +         * 100 
 +         * 600 
 +         * 1200 
 +         * 2400 
 +         * 4800 
 +         * 9600 (Default for EXT mode) 
 +         * 14400 
 +         * 19200 
 +         * 38400 
 +         * 57600 
 +         * 115200 
 +         * 128000 
 +         * 256000 
 + 
 +      * CFL (CFLink Mode) - Messages sent to/from the CFLink Bus, allowing control of other CFLink devices via rules and macros. 115200 is the default <​BAUD>​ rate. Note that CFLink mode connection is only available for RS485-In port. 
 + 
 +<sxh cflink; light: true> 
 +> [F2][20][F3]CCFXSPC[F4]P02:​CFL:​115200:​8:​N:​1:​0[F5][F5] 
 +</​sxh>​ 
 + 
 +=== Query Port Configuration === 
 +This command is used to query and get the current port settings for each control port on the unit. 
 + 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]QCFXSPC[F4]<​PORT>​[F5][F5] ​   \\ Query status of individual ports 
 +> [F2]<​ID>​[F3]QCFXSPC[F4][F5][F5] ​         \\ Query status of all ports 
 +</​sxh>​ 
 + 
 +=== Sending Command to Control External Devices === 
 + 
 +This command is used to send data to control the external device depending on the port used. 
 + 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]TCFXSPW[F4]<​PORT>:<​DATA>​[F5][F5] ​    
 +</​sxh>​
  
 ===== Relay Commands ===== ===== Relay Commands =====
Line 15: Line 74:
 </​sxh>​ </​sxh>​
  
-  * **<​PORT>​** = The relay channel (port) to be controlled. Relay channels would be from ''​P01-P08''​.+  * **<​PORT>​** = The relay channel (port) to be controlled. Relay channels would be from ''​P01-P08'' ​for the 8-channel and ''​P01-P05''​ for the 5-channel.
   * **<​STATE>​** = The command to set the status of relay. ''​0''​ would set the relay to open, ''​1''​ would set the relay to close, ''​T''​ would set the relay to toggle. ​   * **<​STATE>​** = The command to set the status of relay. ''​0''​ would set the relay to open, ''​1''​ would set the relay to close, ''​T''​ would set the relay to toggle. ​
  
Line 21: Line 80:
  
 <sxh cflink; light: true> <sxh cflink; light: true>
-// The reply does not echo the data sent in an effort to reduce bus traffic +< [F2]<​ID>​[F3]RRLYCHA[F4]<​PORT>:<​STATE>​[F5][F5] ​// The reply comes from only the port where the change event happens 
-< [F2]<​ID>​[F3]RIRBSND[F4][F5][F5]+< [F2]<​ID>​[F3]RRLYSTA[F4]<​PORT>:<​STATE>​[F5][F5] ​// The reply comes from all the ports 
 </​sxh>​ </​sxh>​
-If sending multiple ​IR commands ​via a single CFLink ​message, the reply will only happen after all IR commands ​have been sent.+ 
 +To minimize the data traffic on the communication bus, the ''​RRLYCHA''​ will only reflect the affected ports only. It will also be sent as unsolicited messages when buttons on the display panel are set. The ''​RRLYSTA''​ reply will have all port status, separated by pipes. 
 + 
 +===== Dry Contacts ===== 
 + 
 +==== Status Read ==== 
 + 
 +=== Send === 
 + 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]QCFXSTA[F4]<​PORT>​[F5][F5] // query single port 
 +> [F2]<​ID>​[F3]QCFXSTA[F4][F5][F5] ​      // query all ports 
 +</​sxh>​ 
 + 
 +=== Reply === 
 + 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]RCFXSTA[F4]<​PORT>:<​STATE>​[F5][F5] ​ // reply with  
 +> [F2]<​ID>​[F3]RCFXCHA[F4]<​PORT>:<​STATE>​[F5][F5] ​ // auto reporting 
 +</​sxh>​ 
 + 
 +When <​PORT>​ is specified, reply will have status of only specified port. If <​PORT>​ is omitted, reply will have all port states. ''​RCFXCHA''​ will be sent as unsolicited message when port changed. 
 + 
 +==== Mode Configuration ==== 
 + 
 +=== Send === 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]CCFXDCP[F4]<​Port>:<​Mode>:<​Double Tap Time>:<​Hold Time>​[F5][F5] 
 +> [F2]<​ID>​[F3]CCFXDCP[F4]<​Port>:<​Mode>:<​Timeout Time>:<​Trigger State>​[F5][F5] 
 +</​sxh>​ 
 + 
 +=== Reply === 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]RCFXDCP[F4]<​Port>:<​Mode>:<​Double Tap Time>:<​Hold Time>​[F5][F5] 
 +</​sxh>​ 
 + 
 +  * **<​PORT>​** = The relay channel (port) to be controlled. Relay channels would be from ''​P01-P08''​ for the 8-channel and ''​P01-P05''​ for the 5-channel. 
 +  * **<​MODE>​** = ''​N''​ for **Normal** (default), ''​A''​ for **Advanced**,​ ''​T''​ for **Timer**.  
 +  * **<​Double Tap Time>** = Time in 100ths of a second for a double tap to occur within. Valid range (1-65535) (0.1s - 6553.5s). 
 +  * **<Hold Time>** = Time in 100ths of a second for a long press and hold to occur. Valid range (1-65535) (0.1s - 6553.5s).  
 +  * **<​Timeout Time>** = Time in 100ths of a second for a port to stop reporting commands. Valid range (1-65535) (0.1s - 6553.5s). 
 +  * **<​Trigger State>** = When to trigger timer to start and restart. 1 = on close, 0 = on open. Default is “1 On Close” if this param is missing. 
 + 
 +In **Normal** mode, dry contacts work as currently - report state on change, on press and on release. <Double Tap Time> and <Hold Time> can be omitted from command when setting normal mode. 
 + 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]RCFXCHA[F4]<​PORT>:<​STATE>​[F5][F5] // <​STATE>​ = 1 for press or 0 for release. 
 +</​sxh>​ 
 + 
 +In **Timer** mode, dry contacts report on change as normal to start, but do not report any CHA or STA again until the timer goes out. Still report if manually requested via ''​QCFXSTA''​ regardless of timer. 
 + 
 +Each time the port “trigger state” is reached, the timer will restart. Only once it times out (the time elapses with no state changes) will it begin to start sending ​state changes again. 
 + 
 +When the timer times out, it will also send a special reply''​RCFXTUP''​ for indicating the time is up with the port number as the data. For example: 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]RCFXTUP[F4]<​PORT>​[F5][F5] // <​PORT>​ = P01 or P02, etc. 
 +</​sxh>​ 
 + 
 +An example on Timer: 
 + 
 +A command is sent with Port 1 defined as timer mode with timer as 300s, trigger on close. 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]CCFXDCP[F4]P01:​T:​3000:​1[F5][F5]  
 +</​sxh>​ 
 + 
 +-> Port 1 closes: (timer = 0s) 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]RCFXCHA[F4]P01:​1[F5][F5]  
 +</​sxh>​ 
 + 
 +-> 10 secs later, Port 1 closes: (time = 10s) 
 +<no report, timer restarts>​ 
 + 
 +-> 290 secs later from last event, Port 1 closes: (time = 300s)  
 +<no report, timer restarts>​ 
 + 
 +-> 300 secs later from last event, and Port 1 is now open: (time = 600s) 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]RCFXCHA[F4]P01:​0[F5][F5] // reports state 
 +> [F2]<​ID>​[F3]RCFXTUP[F4]P01[F5][F5] // timeout  
 +</​sxh>​ 
 + 
 +Another example: 
 + 
 +^ Time from 0 ^ Event ^ Bus Traffic ^ Timer ^ 
 +|Before 0s| | |inactive| 
 +|0s|Motion trigger on port 1|\xF2<​ID>​\xF3RCFXCHA\xF4P01:​1\xF5\xF5|started (300s)| 
 +|10s|Motion trigger on port 1(port closes)|<​no report>​|re-started(300s)| 
 +|15s|Port 1 opens|<​no report>​|No effect| 
 +|20s|Motion trigger on port 1(port closes)|<​no report>​|re-started (300s)| 
 +|25s|Port 1 opens|<​no report>​|No effect| 
 +|320s|No event|\xF2<​ID>​\xF3RCFXCHA\xF4P01:​0\xF5\xF5|Timer completed| 
 +|~320s|No event|\xF2<​ID>​\xF3RCFXTUP\xF4P01\xF5\xF5|Timer completed| 
 +|350s|Motion trigger on port 1 (port closes)|\xF2<​ID>​\xF3RCFXCHA\xF4P01:​1\xF5\xF5|started (300s)| 
 +|650s|No event|\xF2<​ID>​\xF3RCFXSTA\xF4P01:​1\xF5\xF5| | 
 +|~650s|No event|\xF2<​ID>​\xF3RCFXTUP\xF4P01\xF5\xF5|Timer completed| 
 +|660s|Port 1 opens|<​no report>​|No effect| 
 +|670s|Motion trigger on port 1 (port closes)|\xF2<​ID>​\xF3RCFXCHA\xF4P01:​1\xF5\xF5|Timer “restarts” (300s)| 
 + 
 +In **Advanced** mode, dry contacts will have no reports on press or release. Instead, it reports physical "​gestures"​ - single tap (press), double tap (press) or held on change (press and hold) based on timing configuration:​ 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]RCFXCHA[F4]<​PORT>:<​STATE>​[F5][F5] // <​STATE>​ = S for Single Tap, D for Double Tap OR H for Hold 
 +</​sxh>​ 
 + 
 +For example, let's configure a dry contact as **Advanced** mode P01:A:15:30 where Double Tap time = 1.5 seconds, Hold time = 3.0 seconds 
 + 
 +A Single Tap is reported if the 1x press and 1x release is detected within the double tap time (1.5 seconds). A single tap will not be reported til after the double tap time has lapsed. 
 + 
 +A Double Tap is reported if the 2x presses and 2x releases are detected within the double tap time (1.5 seconds). 
 + 
 +A Hold is then reported if 1x press with no release is detected within the hold time (3 seconds).  
 + 
 +Start is defined by the detection of the first press. End is defined when a report is made. All timings are PER PORT. 
 + 
 +Therefore a report of an event should be either a S, D OR H.  A “single” event CANNOT report ​multiple ​types of presses. 
 + 
 +Valid time values are 000:100 where 100 = 10 seconds 
 + 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]CCFXDCP[F4]<​PORT_CONFIG>​[F5][F5] \\ Send 
 +> [F2]<​ID>​[F3]RCFXDCP[F4]<​PORT_CONFIG>​[F5][F5] \\ Reply 
 +</​sxh>​ 
 + 
 +For Example: 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]CCFXDCP[F4]P01:​A:​15:​300|P02:​N|P03:​N[F5][F5] \\ Send 
 +> [F2]<​ID>​[F3]RCFXDCP[F4]P01:​A:​15:​300|P02:​N|P03:​N[F5][F5] \\ Reply 
 +</​sxh>​ 
 + 
 +===== AC Load Status Read ===== 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]QCFXACS[F4]<​PORT>:<​STATE>​[F5][F5] \\ Query AC Load Status 
 +> [F2]<​ID>​[F3]RCFXACS[F4]<​PORT>:<​STATE>​[F5][F5] \\ Reply 
 +</​sxh>​ 
 + 
 +===== Conditional ​commands ​based on variable states ===== 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]TCFXCON[F4]<​CONDITION>​[F6]<​ACTION>​[F5][F5] ​ \\ Send 
 +> [F2]<​ID>​[F3]RCFXCON[F4]<​BOOLEAN>​[F5][F5] ​               \\ Reply 
 +</​sxh>​ 
 + 
 +Example of command syntax to send: 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]TCFXCON[F4]<​VARIABLE><​OPERATOR><​VALUE>​[F6]<​TARGET_ID>:<​COMMAND>:<​DATA>​[F5][F5] ​ \\ Syntax 
 +> [F2]<​ID>​[F3]TCFXCON[F4]01==1[F6]00:​TRLYSET:​M2|P02:​1[F5][F5]  
 +> [F2]<​ID>​[F3]RCFXCON[F4]TRUE[F5][F5] ​                                                         \\ Reply                                  
 +</​sxh>​ 
 + 
 +  * \xF6 splits the condition and the action. It is a single ​hex byte. The first \xF6 byte in the data should be considered the split location, so that the actual action can contain any byte including \xF6. 
 +  * <​DATA>​ can contain anything, except \xF5\xF5, including additional colons. 
 +  * <​VARIABLE>​ the data represents the variable type and variable character to get the value of, AA-ZZ. This allows you to compare a variable value in the condition. 
 +  * Built in variables for this device are: 
 +       * 00 = Any AC state is on = 1, else all off then = 0. 
 +       * 01 = AC Status 1 (1 = on or 0 = off) 
 +       * 02 = AC Status 2 (1 = on or 0 = off) 
 +       * .... 
 +       * 08 = AC Status 8 (1 = on or 0 = off) 
 +  * <​OPERATOR>​ can be one of the following symbol sequences (always 2 bytes) 
 +       * ==    EQUAL TO 
 +       * !=    NOT EQUAL TO 
 +       * >> ​   GREATER THAN 
 +       * >=    GREATER THAN OR EQUAL TO 
 +       * << ​   LESS THAN 
 +       * <=    LESS THAN OR EQUAL TO 
 +  * <​VALUE>​ must be a digit, 0-65535. This is used (with the <​OPERATOR>​) to compare the state of the <​VARIABLE>​. 
 +  * <​TARGET_ID>​ should be the CFLink ​ID of the unit receiving the commandin plain ascii (range 2 - EF). Single character will work (2-9) or two characters (02-EF). 00 = local device (ie. target ​the same device the condition is running on). 
 +  * For each reply, a boolean ''​TRUE''​ or ''​FALSE'' ​will be returned on each condition evaluation, as the reply data payload. ''​RCFXCON''​ ''​TRUE''​ for example. 
 + 
 +===== Conditional ON and OFF based on AC Status read ===== 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]TRLYCON[F4]<​CONDITION>​|<​ACTION>​[F5][F5] ​ \\ Send 
 +> [F2]<​ID>​[F3]RRLYCON[F4]<​BOOLEAN>​[F5][F5] ​            \\ Reply                                  
 +</​sxh>​ 
 + 
 + 
 +  * <IF AC STATE> = S01:1 (AC state 1 is on) 
 +  * <IF AC STATE> = S01:0 (AC state 1 is off) 
 + 
 +  * <SET PORT STATE> = P01:1 (port 1 L1/NO) 
 +  * <SET PORT STATE> = P01:2 (port 1 L2/NC) 
 +  * <SET PORT STATE> = P01:0 (port 1 L2/NC) 
 +  * <SET PORT STATE> = P01:T (port 1 toggle) 
 + 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]TRLYCON[F4]S01:​1|P01:​1[F5][F5] ​ \\ If AC State 1 is ON, then Set Port 1 to L1 
 + 
 +> [F2]<​ID>​[F3]TRLYCON[F4]S01:​0|P01:​2[F5][F5] ​ \\ If AC State 1 is OFF, then set relay port 1 to L2 
 +> [F2]<​ID>​[F3]TRLYCON[F4]S01:​0|P01:​T[F5][F5] ​ \\ If AC State 1 is OFF, then toggle relay port 1, effectively turning ON circuit 1 when status reads OFF. 
 +> [F2]<​ID>​[F3]TRLYCON[F4]S01:​1|P02:​T[F5][F5] ​ \\ If AC State 1 is ON, then toggle relay port 2. 
 +> [F2]<​ID>​[F3]TRLYCON[F4]SZZ:​1|PZZ:​1[F5][F5] ​ \\ All ports.If AC State 1 is ON, then Set Port 1 to L1, If AC State 2 is ON, then Set Port 2 to L1, etc. until If AC State 8 is ON, then Set Port 8 to L1. 
 +</​sxh>​ 
 + 
 +===== User Variable ===== 
 + 
 +You can use user variables to store strings or values that can be retrieved anytime for use later.  
 + 
 +The ''​CVARSET''​ (Send) command is used to assign a value to the defined user variable. 
 + 
 +=== Data === 
 + 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]CVARSET[F4]<​VARIABLE_NAME>:<​VALUE>​[F5][F5] 
 +</​sxh>​ 
 + 
 +  * **<​VARIABLE_NAME>​** = The name of the user variable. 
 +  * **<​VALUE>​** = The value to be assigned to the variable. 
 + 
 +=== Reply === 
 + 
 +<sxh cflink; light: true> 
 +< [F2]<​ID>​[F3]RVARSET[F4]<​VARIABLE_NAME>:<​VALUE>​[F5][F5]  
 +</​sxh>​ 
 + 
 +There are two variable query commands ​available -  ''​QVARLST''​ command is used to query all available variables and its respective values. ''​QVARGET''​ command is used to query a specific variable value. 
 + 
 +=== Data === 
 + 
 +<sxh cflink; light: true> 
 +> [F2]<​ID>​[F3]QVARLST[F4][F5][F5] \\ Query value for all variables 
 +> [F2]<​ID>​[F3]QVARGET[F4]<​VARIABLE_NAME>​[F5][F5] \\ Query value for specific variable 
 +</​sxh>​ 
 + 
 +  * **<​VARIABLE_NAME>​** = The name of the user variable. 
 +  * **<​VALUE>​** = The value to be assigned to the variable. 
 + 
 +=== Reply === 
 + 
 +<sxh cflink; light: true> 
 +< [F2]<​ID>​[F3]RVARGET[F4]<​VARIABLE_NAME>:<​VALUE>​[F5][F5]  
 +</​sxh>​ 